Benefit of general anesthesia monitored by bispectral index compared with monitoring guided only by clinical parameters. Bispectral index scale bis monitoring and intravenous. The bis index is a processed eeg parameter with extensive validation and demonstrated clinical utility. Bis values fall with initial anaesthetic induction then rise as the patient emerges. Impact of bispectral index monitoring on postoperative. Pdf bilateral bispectral index bisvista monitoring of. Called the bispectral index bis monitor, this noninvasive device can be used without assistance from highly specialized clinicians. Anesthetic management guided by bispectral index monitoring has been demonstrated to facilitate earlier recovery in adults. Bispectral index monitoring gives objective and reliable data where the nurse can base care from, instead of relying mainly from vital signs as well as subjective signs, and thus, pose lesser threats of both undersedation and oversedation. Anesthesia awareness and the bispectral index nejm.
It provides depth of consciousness and sedation monitoring for use in the or, icu, and other clinical settings. However, investigations assessing intracranial neurophysiological events are limited. Nonconstancy of the bispectrum of a time series has been taken as a measure of nongaussianity and nonlinear serial dependence in a stochastic process. Diagnostic and prognostic use of bispectral index in coma. Information and translations of bispectral in the most comprehensive dictionary definitions resource on the web.
Bispectral index monitoring in ischemichypoxic brain injury. Bispectral index is one of several technologies used to monitor depth of anesthesia. Bispectral index monitoring basics article nursingcenter. If the low frequencies are in phase with the high frequencies, the resultant high bis values reflect good cortical integration. Identify potential limitations to using bis monitors for monitoring of sedation in icu patients receiving neuromuscular blocking agents. Bis monitors are used to supplement guedels classification system for determining depth of anesthesia. Originally, the device was approved only for monitoring hypnosis and has now received an indication for reducing the incidence of intraoperative awareness during anesthesia. Bispectral index monitoring is a useful tool to accomplish this, because it can provide objective information as to the degree of sedation in these critically injured patients. Bispectral analysis is a signal processing methodology that. The bis monitor is the first quantitative eeg index introduced into clinical practice as a monitor to assess the depth of anesthesia. Bispectral index bis is one of several technologies used to monitor depth of anesthesia. Correlation of bispectral index with endtidal sevoflurane concentration and age in infants and children article pdf available in bja british journal of anaesthesia 953. Bispectral index monitoring bis is a continuously processed eeg measure to assess depth of anaesthesia 29.
Bispectral index for titrating sedation in ards patients. The bispectral index bis is a variable derived from the electroencephalograph eeg that has been reported to have the ability to measure the hypnotic component of the anesthetic state. Use of bispectral index bis for monitoring of total intravenous anaesthesia in pediatric patients. It is unique among the quantitative electroencephalogram qeeg parameters because it integrates several independent descriptors of the eeg into a single variable. This article explains how bis monitoring works and describes the authors experience with bis monitoring in patients undergoing elective synchronized electrical cardioversion. The bispectral index monitor is connected to a sensor which is placed on the forehead of the patient. Today, the bis index remains the most validated form of consciousness or brain function monitoring used within the clinical context of anesthesia and sedation care. The surgical pleth index, or spi, is a digit that may be used to monitor the patients hemodynamic responses to surgical stimuli and analgesic medications. Surgical pleth index for monitoring the patients hemodynamic responses to surgical stimuli and analgesic medication under general anesthesia what is the surgical pleth index.
The bispectral index bis, a measure of depth of anesthesia and sedation, is a complex index, but it predominantly quantifies, on a scale of 0 to 100, the degree of coherence among different frequencies in the electroencephalograph eeg signal. Bispectral index bis monitoring during propofolinduced sedation and anaesthesia. The depth of sedation is calculated by measuring cerebral electric activity via an electroencephalogram eeg. This manuscript describes the current state of knowledge on the bispectral index. Utility of bilateral bispectral index bis monitoring in. Electroencephalogram and bispectral index monitoring. It consists of a sensor, a digital signal converter, and a monitor. Bispectral index and other processed parameters of electroencephalogram. Bispectral index and other processed parameters of. The bis view system processes raw eeg signals to produce a single number, called the bispectral index, or bis, which correlates with the patients level of. Bispectral index, electroencephalography, coma, vegetative state, minimally conscious state, brain injury introduction the assessment of consciousness level in severely brain damaged patients represents a real challenge. The flotationrestricted environmental stimulation technique rest, a process of floating horizontally and face up inside a quiet, dark tank filled with magnesium sulfatesaturated water held at normal skin temperature, has been associated with multiple benefits 1, 2. Bispectral index monitoring bispectral index monitoring involves the use of an electronic device that converts eeg waves into a number.
From 2006 to 2009, 292 consecutive patients undergoing. One may have to use a monitor of cortical suppression to maintain the optimal level of sedation and hypnosis. The bispectral index, a non invasive procedure of recent introduction, has been used and applied in the operating room and the intensive care unit in patients with sedation, barbiturate coma, status epilepticus, hypoglycemia, hypothermia, low cerebral flow, assisted mechanical ventilation and in patients undergoing to non invasive procedures at. When the bispectral index bis can give false results.
The bis view monitoring system is a userconfigurable patient monitoring system designed to monitor the hypnotic state of the brain based on acquisition and processing of eeg signals. Bis view monitoring system franks hospital workshop. Bispectral index monitoring an overview sciencedirect. Bis monitors are intended to replace or supplement guedels classification system for determining depth of. Use of bispectral index bis for monitoring of total. The resultant eeg is a low voltage 1 mv signal, requiring amplification and signal processing. There are several alternative technologies to quantify the depth of anesthesia, but only the bis and snap monitors are licensed in canada. A bispectral index bis monitor is commonly utilized to assess depth of sedation when administering sedative, hypnotic, or anesthetic agents during surgical and medical procedures. Background awareness during anesthesia is a serious complication with potential longterm psychological consequences.
This number, statistically derived from raw eeg data, indicates the depth or level of a patients sedation and provides a direct measure of the effects of sedatives and anesthetics on the brain. Bispectral index bis monitoring during propofolinduced. Update on bispectral index monitoring sciencedirect. Due to similarities in eeg synchronization between anesthesia and sleep, several studies have assessed bis as a sleep monitor with contradictory results. Download free acrobat reader dc software, the only pdf viewer that lets you read, search, print, and interact with virtually any type of pdf file. Bis technology measures only the hypnotic component of anesthesia. Multidrug therapy for epilepsy influenced bispectral. Bilateral bispectral index bisvista monitoring of cerebral hypoperfusion in patients with carotid artery stenosis undergoing coronary artery bypass surgery. Bispectral index in a sleeping volunteer throughout the night 1 rem sleep, 0 awake, 1 and 2 light sleep, 3 and 4 slow wave sleep the aim of this present study was to use the bis to quantify the sleep patterns found in adult patients in the icu, and to attempt to identify any particular clinical. Use of the bispectral index bis, developed from a processed electroencephalog. Titrating anesthetic agents to a specific bispectral index during general anesthesia in adults and children over 1 year old allows the anesthetist to adjust the amount of anesthetic agent to the needs. The bispectral index bis, aspect medical systems, natick, ma is a complex parameter, composed of a combination of time domain, frequency domain, and high order spectral subparameters 5. As opposed to coma, patients in a vegetative state vs open their eyes, indicating restoration of sleep. Monitoring consciousness using the bispectral index during.
A new bispectral test for nonlinear serial dependence elena rusticelli, richard a. Only with adobe acrobat reader you can view, sign, collect and track feedback, and share pdfs for. Bispectrum and bicoherence may be applied to the case of nonlinear interactions of a continuous spectrum of propagating waves in one dimension bispectral measurements have been carried out for eeg signals monitoring. A new bispectral test for nonlinear serial dependence. Brazilian journal of anesthesiology english edition volume 67, issue 1, januaryfebruary 2017, pages 7284. It was also shown that bispectra characterize differences between families of musical instruments. Bispectral index monitor definition of bispectral index. Bispectral index bis monitoring is commonly used in clinical practice for guiding anesthetic administrationand provides an index based on relationships between eeg components. It is derived utilizing a composite of measures from eeg signal processing techniques including bispectral analysis, power spectral analysis, and time domain analysis. Bispectral index monitoring allows faster emergence and. The cerebral cortex is characterized by a rich network of neurons, particularly pyramidal cells, generating millions of small current loops that can be detected as the electroencephalogram eeg. Bispectral index monitoring in pediatric anesthesia. Bispectral index monitor ontario healthtechnology assessment series 2004. Recent preliminary data also suggest that titration of drugs to achieve.
The bispectral index bis monitor covidien, boulder, co, usa has been used as a surrogate for depth of anesthesia in and has also been posited to improve recovery from surgery and general anesthesia. Compare the recommendations for the use of bispectral index bis monitors between the guidelines for painagitationdelirium and neuromuscular blockade. For statistical analysis of these data in time domain it is necessary to know that eeg is a non deterministic signal, in other words, it is not possible. Multidrug therapy for epilepsy influenced bispectral index after a bolus propofol administration without affecting propofols pharmacokinetics. Benefit of general anesthesia monitored by bispectral. Bis index values are the result of two particular innovations. The bis monitor could have direct or indirect effects on recovery. We evaluated the association of bispectral index with postoperative neurological outcome and delirium in patients undergoing aortic surgery. The bispectral index bis is a multifactorial parameter derived from the electroencephalogram eeg, which allows monitoring of the hypnotic component of anesthesia. Since 5 years now the bispectral index scale bis monitor is the one and only clinical available device that has culminated from this search and became available for clinical practice. It was obtained from the algorithm based on the analysis of a large number of eegs from volunteers and patients undergoing sedation and general anesthesia with different anesthetic agents. Bispectral index monitoring can facilitate anesthesia care.
798 216 332 785 1539 1487 331 938 194 371 640 10 296 890 180 254 1316 142 37 386 784 308 724 495 1498 1023 1085 23 360 1400 196 892 1195 954 1316 913 7 1083 850 392 943 382 18